The right dimensioning of an air pipe is very important: A pressure decrease from 6 bar to 5 bar reduces the power of the machines and tools by up to 25%. If the final compression pressure is increased by 1 bar to compensate for decrease in pressure, costs for operating power increase by 10%.
Pressure decrease 0,1 bar on operating pressure 7 bar. The diagram below allows to determinate the diameter of the main line. By ring line halve the flow rate and the distance.
| Volumenstrom | Gesamtlänge in m = Länge der Rohrleitung + adäquate Rohrlänge für Einbauteile | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| l/min. | cfm | 25 | 40 | 60 | 80 | 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 800 | 1000 |
| 400 | 14,16 | 15 | 15 | 18 | 18 | 20 | 20 | 22 | 22 | 22 | 25 | 25 | 25 | 28 | 28 |
| 500 | 17,70 | 15 | 18 | 18 | 20 | 20 | 22 | 22 | 25 | 25 | 28 | 28 | 28 | 40 | 40 |
| 750 | 26,55 | 18 | 20 | 20 | 22 | 22 | 25 | 28 | 28 | 28 | 40 | 40 | 40 | 40 | 40 |
| 1200 | 42,48 | 22 | 22 | 25 | 28 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 |
| 1500 | 53,10 | 22 | 25 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 |
| 2000 | 70,80 | 25 | 28 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 |
| 3000 | 106,20 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 60 | 60 | 60 |
| 4800 | 169,92 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 |
| 7200 | 254,88 | 40 | 50 | 50 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
| 10800 | 382,32 | 50 | 60 | 60 | 60 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |||
| 15000 | 531,00 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |||||
| 20000 | 708,00 | 80 | 80 | 80 | 80 | 80 | 80 | ||||||||